BSK-RPR-1

Technical documentation Installation, mounting and operating instructions BSK-RPR Fire damper Fig.: BSK-RPR with B10 drive USABILITY CERTIFICATES • • • Performance Reliability Certificate according to EU-Bau PVO 0761 – CPR – 0245 EC Certificate of Conformity 0761 – CPD – 0263 Declaration of Performance DoP-BSK-RPR-2017-08-09 PERFORMANCE DATA • • For automatic locking of fire lobbies For use or connection of a smoke release device with abZ (e.g. SCHAKO smoke detection system RMS) in connection with suitable release devices (e.g. spring return actuator) SPECIAL FEATURES CLASSIFICATION AND STANDARDS • • • Classification according to EN 13501-3, depending on the mounting situation EI 90 (ve, ho i↔o) S Product standard EN 15650 Test standard EN 1366-2 SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen ATEX version available (at an extra charge) Extensive uses and applications Housing leakage class C according to EN 1751 For optimum integration into the building control system via the SCHAKO EasyBus signalling and switching bus system or the SCHAKO BKSYS fire damper mini-controller

 Abrir la página 1 del catálogo
BSK-RPR-2

Fire Damper Model BSK-RPR Technical documentation Table of Contents Construction subject to change. No return possible

 Abrir la página 2 del catálogo
BSK-RPR-3

Fire Damper Model BSK-RPR Technical documentation Description DESCRIPTION Fire dampers, installed in ventilation ducts (air conditioning systems), serve for the automatic locking of fire lobbies. The fire damper BSK-RPR corresponds to EN 15650, EN 135013 and EN 1366-2. The BSK-RPR has been tested according to EN 1366-2 in compliance with Declaration of Performance no. DoP-BSK-RPR-201708-09. It has the Performance Reliability Certificate according to EU-Bau PVO 0761-CPR-0245 and the EC Certificate of Conformity 0761-CPD-0263. Its category according to EN 13501-3 is EI 90 (ve, ho i ↔ o) S. According...

 Abrir la página 3 del catálogo
BSK-RPR-4

Fire Damper Model BSK-RPR Technical documentation Models and dimensions MODELS AND DIMENSIONS BSK-RPR – Nominal sizes 100 to ≤ 250 BSK-RPR-S (plug-in connection) Fig. 1: Dimension BSK-RPR-S – Nominal sizes 100 to ≤ 250 BSK-RPR-S with mounting frame AR (Mounting frame AR only possible in -S design, pre-mounted ex works, delivery in loose form not possible) Fig. 2: Dimension BSK-RPR-S with mounting frame AR – Nominal sizes 100 to ≤ 250 BSK-RPR-F (flanged connection) Fig. 3: Dimension BSK-RPR-F – Nominal sizes 100 to ≤ 250 1 2 3 4 Housing Damper leaf Hand lever Locking profile Construction subject...

 Abrir la página 4 del catálogo
BSK-RPR-5

Fire Damper Model BSK-RPR Technical documentation Models and dimensions BSK-RPR – Nominal sizes > 250 to 500 BSK-RPR-S (plug-in connection) Fig. 4: Dimension BSK-RPR-S – Nominal sizes >250 to 500 BSK-RPR-S with mounting frame AR (Mounting frame AR only possible in -S design, premounted ex works, delivery in loose form not possible) Fig. 5: Dimension BSK-RPR-S with AR – Nominal sizes > 250 to 500 BSK-RPR-F (flanged connection) Fig. 6: Dimension BSK-RPR-F – Nominal sizes > 250 to 500 1 2 3 4 Housing Damper leaf Hand lever Locking profile Construction subject to change. No return possible Trigger...

 Abrir la página 5 del catálogo
BSK-RPR-6

Fire Damper Model BSK-RPR Technical documentation Models and dimensions Rubber lip seal for BSK-RPR-S Model BSK-RPR-S is delivered as standard with a rubber lip seal. Flange bores BSK-RPR-F SCHAKO ASG-RF / VT-RF / FS-RF: Flange bores suitable for BSK-RPR-F Fig. 8: Release device BSK-RPR Construction subject to change. No return possible

 Abrir la página 6 del catálogo
BSK-RPR-7

Fire Damper Model BSK-RPR Technical documentation Models and dimensions Damper leaf projecting ends Nominal size * Extension piece (on site) necessary Table 3: Damper leaf projecting ends BSK-RPR-S "a"= 50 Minimum distance between the front edge mm: of the open damper leaf and the security grille (ASG) or flexible connection piece (FS). Nominal size * Extension piece (VT-RF) necessary Table 4: Damper leaf projecting ends BSK-RPR-F Construction subject to change. No return possible

 Abrir la página 7 del catálogo
BSK-RPR-8

Fire Damper Model BSK-RPR Technical documentation Models and dimensions UseThe fire damper type BSK-RPR can be fitted as shown in the following table. Use 1) Installation only in connection with a ventilation duct devoid of openings (fire resistance duration 90 min.) between the BSK-RPR and the fire-resistant wall to be protected. Mounting only allowed in conjunction with mounting frame AR. 2) The exact wall thickness/es must be taken into account and specified when ordering. For installation, the accessories for sliding ceiling connection plus mounting frame AR are required. 3) At nominal sizes...

 Abrir la página 8 del catálogo
BSK-RPR-9

Fire Damper Model BSK-RPR Technical documentation Installation details General information • During mounting or installation, there is a risk of injuries. To avoid any possible injuries, personal protective equip-ment (PPE) must be worn. • Fire dampers must be installed such that external forces do not impair their permanent functioning. During mounting it may be required to provide reinforcements for the housing or the like. The requirement of statically load-bearing lintels may have to be taken into consideration. • Improper transport/handling may result in damage/func-tional impairment. In...

 Abrir la página 9 del catálogo
BSK-RPR-10

Fire Damper Model BSK-RPR Technical documentation Installation details Installation on solid walls with mounting frame AR Nominal sizes 100 to 500 - (dry installation)  Installation on solid walls (shaft walls, shafts, ducts and fire walls) made of, for example, concrete, masonry according to EN 1996 or DIN 1053; solid plaster wall boards according to EN 12859 or DIN 18163; apparent density ≥ 450 kg/m³ and wall thickness W ≥ 100 mm only in conjunction with mounting frame AR.  The distance of the fire dampers to one another must be at least 200 mm. (For nominal sizes 100 - 250, mounting is allowed...

 Abrir la página 10 del catálogo
BSK-RPR-11

Fire Damper Model BSK-RPR Technical documentation Installation details Installation away from solid walls with mounting frame AR Nominal sizes 100 to 500 - (dry installation)  Installation away from solid walls (shaft walls, shafts, ducts and fire walls) made of, for example, concrete, masonry according to EN 1996 or DIN 1053; solid plaster wall boards according to EN 12859 or DIN 18163; apparent density ≥ 450 kg/m³ and wall thickness W ≥ 100 mm only in conjunction with mounting frame AR.  When fitting the fire damper away from solid walls, it must be suspended from the ceiling.  Installation...

 Abrir la página 11 del catálogo

Todos los catálogos y folletos técnicos SCHAKO KG

  1. CNVA

    32  Páginas

  2. FKW

    28  Páginas

  3. FBS

    18  Páginas

  4. PIL

    23  Páginas

  5. MWS / MWK

    23  Páginas

  6. DSCXL

    17  Páginas

  7. DSCPL

    16  Páginas

  8. BKSYS

    18  Páginas

  9. DKA

    6  Páginas

  10. VMPR/VMPQ

    29  Páginas

  11. DSCU

    18  Páginas

  12. DSCP

    15  Páginas

  13. DQJP

    9  Páginas

  14. AUDIX®

    25  Páginas

  15. DSC

    37  Páginas

  16. DO

    10  Páginas

  17. VRAQ

    46  Páginas

  18. UEKU

    6  Páginas

  19. UEK

    6  Páginas

  20. VOLKOM

    6  Páginas

  21. STV

    8  Páginas

  22. DQJ

    38  Páginas

  23. ALAS-F 125

    6  Páginas

  24. ALPETY

    16  Páginas

  25. CTT

    23  Páginas

  26. KWB

    19  Páginas

  27. FKU

    31  Páginas

  28. FKF

    29  Páginas

  29. DBB

    27  Páginas

  30. TVO

    8  Páginas

  31. AL

    23  Páginas

  32. NBS

    30  Páginas

  33. JK

    16  Páginas

  34. HK

    16  Páginas

  35. DISA-H

    34  Páginas

  36. DISA-360

    32  Páginas

  37. DISA-300

    51  Páginas

  38. CNV

    28  Páginas

  39. Aquaris-Silent

    38  Páginas

  40. DISA-W

    41  Páginas

  41. CULTRA-Studioline

    24  Páginas

  42. BDA

    11  Páginas

  43. PILB/PILBR

    33  Páginas

  44. DAV

    19  Páginas

  45. 4DE

    18  Páginas

  46. 4DF

    15  Páginas

  47. DQC

    16  Páginas

  48. DQDL

    16  Páginas

  49. IDA

    21  Páginas

  50. IKA

    23  Páginas

  51. ZMD

    17  Páginas

  52. DQF

    15  Páginas

  53. DQJSL

    17  Páginas

  54. DQJSLC

    17  Páginas

  55. DHV

    18  Páginas

  56. DSA

    18  Páginas

  57. DSARR

    7  Páginas

  58. QA

    30  Páginas

  59. PUSH

    23  Páginas

  60. WQA

    12  Páginas

  61. DSX

    25  Páginas

  62. DSX-XXL

    23  Páginas

  63. DSX-XXL-W

    25  Páginas

  64. SIA

    7  Páginas

  65. SAR/SAQ/SARP

    13  Páginas

  66. WDA

    32  Páginas

  67. BSG

    19  Páginas

  68. KG

    19  Páginas

  69. IB-Q

    21  Páginas

  70. IB-R

    15  Páginas

  71. PA

    32  Páginas

  72. DBBR

    6  Páginas

  73. KGRR

    17  Páginas

  74. DBBRR

    11  Páginas

  75. WGARR

    7  Páginas

  76. WGA

    29  Páginas

  77. ALA-R

    4  Páginas

  78. ALA-SO

    4  Páginas

  79. ALAS

    10  Páginas

  80. ALAS-P

    5  Páginas

  81. EBE/EBP

    52  Páginas

  82. DKG

    6  Páginas

  83. MBE/MBP

    27  Páginas

  84. PIANO

    27  Páginas

  85. VAS

    26  Páginas

  86. VRAPPs

    20  Páginas

  87. VRAR

    52  Páginas

  88. MAK

    15  Páginas

  89. RS

    15  Páginas

  90. EasyBus

    29  Páginas

  91. BKP-EN

    40  Páginas

  92. BAK-240

    6  Páginas

  93. BAK-250

    14  Páginas

  94. AUDIX

    2  Páginas

  95. DISA

    4  Páginas

  96. UC-OH²

    2  Páginas

  97. IGA

    2  Páginas

  98. CDD

    2  Páginas

  99. MINOPAB (2025)

    6  Páginas

  100. ERK-SO

    43  Páginas

  101. MINODSA

    6  Páginas

  102. LAQ

    11  Páginas

  103. BKA-EN

    79  Páginas

  104. CPL

    15  Páginas

  105. VREX

    26  Páginas

  106. VQEX

    17  Páginas

  107. VPEX

    18  Páginas

  108. SVA-FS

    11  Páginas

  109. NRWG

    22  Páginas

  110. COMBIDSC

    26  Páginas

  111. SS-K

    6  Páginas

  112. GREENKIT

    20  Páginas

  113. SVA-FF

    15  Páginas

  114. SGA

    5  Páginas

  115. MKAR_MKAQ

    13  Páginas

  116. KF

    4  Páginas

  117. FLAQ

    11  Páginas

  118. FG

    14  Páginas

  119. ERK-MB

    38  Páginas

  120. BKP-EN Fire damper

    40  Páginas

  121. BKA-UE

    35  Páginas

  122. BAK-240

    16  Páginas

  123. Aquaris_KWB

    20  Páginas

  124. DQJF

    12  Páginas

  125. DQJA/DQJR

    10  Páginas

  126. COMBIDQJ

    11  Páginas

  127. COMBIPIL

    11  Páginas

  128. AUDIX®-AW

    20  Páginas

  129. AUDIX®-ÜSG

    13  Páginas

  130. LK

    12  Páginas

  131. ALA

    4  Páginas

  132. DKAPPs

    6  Páginas

  133. VAQS

    19  Páginas

  134. VARS

    26  Páginas

  135. RS-F

    7  Páginas

  136. DISA-Family

    4  Páginas

  137. RMS

    11  Páginas

  138. TSR

    5  Páginas

  139. VLV

    31  Páginas

  140. MBM

    10  Páginas

  141. LL

    7  Páginas

  142. RR-Complete

    41  Páginas

  143. MINODSX

    6  Páginas

  144. SPB

    10  Páginas

  145. DISA-H

    34  Páginas

  146. AQUARIS SILENT

    38  Páginas

  147. NBS

    24  Páginas

  148. JK-LP/JK-LU

    15  Páginas

  149. HKP / HKU

    16  Páginas

  150. FKW

    16  Páginas

  151. FLARE

    13  Páginas

  152. RF

    7  Páginas

  153. KGF

    9  Páginas

  154. SVA-FF

    8  Páginas

  155. BKA-Ü

    35  Páginas

Catálogos archivados

  1. DISA-B

    32  Páginas

  2. DISA-601

    41  Páginas

* Los precios no incluyen impuestos, gastos de entrega ni derechos de exportación. Tampoco incluyen gastos de instalación o de puesta en marcha. Los precios se dan a título indicativo y pueden cambiar en función del país, del coste de las materias primas y de los tipos de cambio.